EICR2208 / J.S. Francisco / 17 Oct 2018 / George Furnace
Electrical Installation Condition Report
Inspection score
50.00%
Failed items
0
Created actions
0
Electrical Installation Certificate No.
EICR2208
Client
J.S. Francisco
Location
203 W 14th St, Casper, WY 82601, USA
Conducted on

17th Oct, 2018

1:52 PM +08

Prepared by
George Furnace
Audit
50.00%
Purpose for which this report is required
Periodic Inspection
Date of last inspection and testing carried out

15th Oct, 2017

Previous periodic inspection or condition report no.
EICR2207
Details of Installation
0.00%
Are the installation records available?
No
Description of premises
Industrial
Estimated age of the electrical installation
7 years
Extent of the Installation and Limitations of the Inspection and testing
Extent of the electrical installation covered by this report
The whole of the electrical installation with the exception of: 1) Central heating, fire alarm, intruder alarm, emergency lighting wiring, controls, and operation. 2) Wiring in lost spaces. 3) PAT Testing
Agreed limitations (including the reasons), if any, on the inspection and testing
1) Insulation resistance performed between L//N to E for some circuits to save disconnecting equipment and removing lamps. 2) Zs tests at all accessible sockets - some are not accessible 3) Samples of accessory per circuit removed and replaced for inspection to prevent unnecessary damage. 4) Service fuse information obtained by enquiry
Operational limitations including the reasons
1) Cables and enclosures concealed under the floor in walls or within the fabric of a building. 2) Unable to inspect support, terminations, zones, fire barriers, brand I/II separation.
Summary of the condition of the installation
100.00%
General condition of the installation (in terms of electrical safety)
Generally in good condition, but low insulation resistance readings on some. Circuits indicate degrading of some cables and/or ingress into some fittings and junctions.
Overall assessment of the installation
Safe
Documentation
Documentation / Click + to add media information for documentation
Documentation / Click + to add media information for documentation / Photo 1
Take a photo of any significant information (e.g. faulty wires, damaged equipment, etc)
Photos
Description
low resistance reading
Documentation / Click + to add media information for documentation / Photo 2
Take a photo of any significant information (e.g. faulty wires, damaged equipment, etc)
Photos
Description
Faulty wires
Documentation / Click + to add media information for documentation / Photo 3
Take a photo of any significant information (e.g. faulty wires, damaged equipment, etc)
Photos
Description
Faulty wires
Documentation / Click + to add media information for documentation / Photo 4
Take a photo of any significant information (e.g. faulty wires, damaged equipment, etc)
Photos
Description
Faulty wires
Completion
Reviewed and confirmed by (Full Name and Signature of Qualified Supervisor of the Approved Contractor)
George Furnace
17th Oct, 2018 2:49 PM +08
Photos